Skip to content

MCP servers › com.thegrateguys › tools

MCP server · registry snapshot 2026-11-17 · last tested 2026-11-17

tools MCP server

Registry name com.thegrateguys/tools

The Grate Guys Tools — the publisher's title

by thegrateguys.com · domain (the registry's namespace rule)

Planning calculators for metal grating, drainage covers and fabrication. — the publisher's description

1 of 2 record checks metRead-only · tools listed 2026-11-17version 1.0.0streamable HTTP15 tools

Summary

com.thegrateguys/tools is a remote MCP server listed in the official MCP registry at version 1.0.0, under the namespace of the domain thegrateguys.com. On 2026-11-17 ProtocolProbe connected to it in read-only mode and read its inventory: 15 tools, 0 resources and 0 prompts.

Record checks

1 of 2 record checks met · 7 do not apply

  • met: Registry entry is active and says how to run it
  • not met: Source repository link opens
  • not applicable: Repository is not archived
  • not applicable: Code pushed to the repository in the 90 days before our check
  • not applicable: Repository publishes a security policy (SECURITY.md)
  • not applicable: Package names its licence with a standard (SPDX) identifier
  • not applicable: The version the registry lists can be installed and is not withdrawn
  • not applicable: npm package carries build provenance (attestation)
  • not applicable: No known critical or high advisory in the package or its dependencies
  • Not ranked by downloads: a remote server publishes no download figure
  • Not ranked by stars: no public GitHub repository

From public records, not a safety rating. Each check with its reason

Operate this server? Correct a fact · README badge · Run the checks yourself · Claim it

Key facts

Runs
remote (hosted by the publisher)
Transport
streamable HTTP
Your own values
none declared (not a guarantee)
Sign-in
none needed to open a session
Tools
15
Last tested
2026-11-17

Tool list size

10,202 tokens on Claude Opus 5.5

Added to every request that loads this server's tools (15 tools). Counted with Anthropic's token counter on 2026-11-17, from the tool list we read on 2026-11-17. Median across 28,560 counted servers: 2,657 tokens. How it is counted

How a client gets in

Connects without signing in

Read from the server's public metadata on 2026-11-17 (thegrateguys.com), in our read-only connection; no tool was called. It may have changed since. How it is read

Tool list at the three APIs

Not sent yet for this version (1.0.0).

Add to your client

How fresh this is

Live-tested
yes, a real session (not a text-only review)
Last tested
2026-11-17
Mode
read-only (no tool calls)
Latest version
1.0.0, published 2026-11-16 (registry, as of the 2026-11-17 snapshot)
First listed version
2026-11-16 (earliest version still in the registry; older removed versions would be earlier)
Registry data
snapshot 2026-11-17
Package and repository
checked 2026-11-17
Engine
mcp-runtime-engine@0.1.0 · sdk@1.32.0

Dead or stale signals

None found in the records we hold

Looked for and not found: deprecated in the registry. Does not apply: listed version cannot be installed or is withdrawn; repository link does not open; repository archived; no push in over 365 days. Each line is a dated fact from a public record. It does not say whether the server still works, and a record can change after the date shown.

Changes since the last refresh

New in the registry: not in the list of 2026-11-16, listed on 2026-11-17 with version 1.0.0 (published 2026-11-16).

Source: the official MCP Registry list on 2026-11-16 and on 2026-11-17.

What it is

What does this server offer?

Observed inventory
15tools
0resources
0prompts

None of its 15 tools are described as changing anything. For 15 the reading was uncertain, so no mark is shown.

  • bar_grating_load_calculator

    “Finds the lightest welded steel bearing bar (19-W-4 or 15-W-4, smooth or serrated) that carries a clear span and load within a deflection limit.”

    Publisher declares: read-only yes

    9 inputs
    • span_ftnumber“Clear span in feet, measured in the direction of the bearing bars, 0.5 to 12.”
    • span_innumber“Clear span in inches (6 to 144).”
    • span_mmnumber“Clear span in millimetres (152 to 3658).”
    • loadstring“ped = pedestrian, 100 lb/sq ft with a 1/4 in deflection limit; uni = uniform load you give in value; con = concentrated load at mid-span you give in value.”
    • valuenumber“The load to check when load is uni (lb/sq ft) or con (lb per ft of grating width).”
    • deflectionstring“Deflection limit in inches, span240 (span / 240), span360 (span / 360) or none (strength only).”
    • patternstring“19-W-4 (1-3/16 in bar centres), 15-W-4 (15/16 in) or both.”
    • surfacestring“Serrated bars are calculated 1/4 in shallower.”
    • area_sqftnumber“Optional total grating area for an approximate total weight.”
  • bar_grating_load_tables

    “Looks up the safe uniform load (U), safe concentrated load (C), deflections and weight for welded steel bar grating by bearing bar size and span.”

    Publisher declares: read-only yes

    4 inputs
    • patternstring“19-W-4 or 15-W-4 pattern.”
    • surfacestring“Serrated bars act 1/4 in shallower.”
    • barstring“Optional bearing bar size, depth x thickness in inches, for example 1-1/4x3/16.”
    • span_ftnumber“Optional clear span in feet (1 to 12).”
  • aluminum_stainless_bar_grating_load_calculator

    “Safe load, deflection and the lightest bearing bar for aluminum 6063-T6 and stainless 304, 316, 304L and 316L bar grating at 1-3/16 in bar centres.”

    Publisher declares: read-only yes

    6 inputs
    • materialstring“Aluminum 6063-T6, stainless 304 or 316, or stainless 304L or 316L.”
    • span_innumber“Clear span in inches, 24 to 108 (the range of the published tables).”
    • span_mmnumber“Clear span in millimetres, 610 to 2743.”
    • loadstring“ped = pedestrian, 100 lb/sq ft with a 1/4 in deflection limit; uni = uniform load you give in value; con = concentrated load at mid-span you give in value.”
    • valuenumber“The load to check when load is uni (lb/sq ft) or con (lb per ft of grating width).”
    • deflectionstring“Deflection limit in inches, span240 (span / 240), span360 (span / 360) or none (strength only).”
  • accessible_grating_opening_checker

    “Checks the clear opening between bearing bars against the Ontario Building Code 13 mm limit for barrier-free paths of travel, and the widest bar spacing that would pass.”

    Publisher declares: read-only yes

    3 inputs
    • patternstring“19-W-4 (1-3/16 in centres), 15-W-4 (15/16 in centres) or custom (give spacing_in).”
    • spacing_innumber“Bearing bar centre-to-centre spacing in inches.”
    • bar_thickness_innumber“Bearing bar thickness in inches, for example 0.125 (1/8), 0.1875 (3/16), 0.25 (1/4).”
  • galvanizing_coating_thickness_calculator

    “Minimum average hot-dip galvanized coating grade by steel category and thickness, in mils, microns and ounces of zinc per square foot, with total zinc for a surface area.”

    Publisher declares: read-only yes

    4 inputs
    • categorystring“shapes = structural shapes (angles, channels, beams); strip = strip and bar; plate; pipe = pipe and tubing; wire; rebar = reinforcing bar.”
    • thickness_innumber“Steel thickness in inches.”
    • thickness_mmnumber“Steel thickness in millimetres.”
    • area_sqftnumber“Optional surface area to be coated, for the minimum zinc weight.”
  • guard_and_railing_code_checker_ontario

    “Whether a guard is required, its minimum height, opening limit, climbing rule and design loads under the Ontario Building Code Part 9 and Part 3 for a described situation.”

    Publisher declares: read-only yes

    11 inputs
    • locationstring“dwelling = within a dwelling unit; exthouse = exterior serving one dwelling unit; part9 = other Part 9 building; exit3 = required exit in a larger (Part 3) bui…”
    • usestring“normal = ordinary guard; equip = access way to an equipment platform where many people are improbable.”
    • unitstring“Unit of every length below.”
    • dropnumber“Drop to the adjacent surface within 1.2 m (4 ft).”
    • height_above_gradenumber“Walking surface height above grade.”
    • planned_heightnumber“Guard height you plan.”
    • openingnumber“Largest opening: the widest sphere that passes through the guard.”
    • stair_trianglenumber“Optional stair triangle gap, widest sphere.”
    • industrialboolean“Industrial occupancy.”
    • maintenance_onlyboolean“Access for maintenance only.”
    • loading_dockboolean“Loading dock.”
  • steel_stair_calculator_ontario

    “Allowed riser counts, riser height, tread run, flights, width, headroom and handrail height for a total rise under Ontario Building Code Part 9.”

    Publisher declares: read-only yes

    8 inputs
    • stair_typestring“private = inside or outside a house or single dwelling unit; public = every other stair; service = serves service rooms only (Table 9.8.4.1.).”
    • locationstring“dwelling = within a dwelling unit or house; exitres = exit or public stair, residential building; exitother = exit or public stair, other building.”
    • unitstring“Unit of every length below.”
    • total_risenumber“Total rise, finished floor to finished floor.”
    • runnumber“Tread run you want (nosing to nosing).”
    • widthnumber“Clear stair width.”
    • headroomnumber“Clear headroom over the stair.”
    • handrailnumber“Handrail height above the nosing line.”
  • steel_weight_calculator

    “Theoretical weight of carbon steel plate, flat bar, round bar, square bar, angle, square or rectangular tube and round pipe, in pounds and kilograms.”

    Publisher declares: read-only yes

    13 inputs
    • shapestring“plate or sheet, flat bar, round bar, square bar, angle, square or rectangular tube, round pipe or tube.”
    • unitstring“Unit of every size and the length.”
    • widthnumber“Width: plate, flat bar, tube.”
    • thicknessnumber“Thickness: plate, flat bar, angle.”
    • diameternumber“Diameter: round bar.”
    • sidenumber“Side: square bar.”
    • leg_anumber“Leg A: angle.”
    • leg_bnumber“Leg B: angle.”
    • heightnumber“Height: rectangular tube.”
    • wallnumber“Wall thickness: tube and pipe.”
    • outside_diameternumber“Outside diameter: pipe.”
    • lengthnumber“Length of one piece.”
    • quantitynumber“Number of pieces.”
  • trench_drain_grate_load_class

    “The EN 1433 load class, A 15 to F 900, and its test load in kN for where a trench drain goes and what drives or rolls over it.”

    Publisher declares: read-only yes

    1 input
    • applicationstring“footpath = Footpath, patio, pool deck or cycle path; domestic-driveway = Domestic driveway (cars and light vans); private-road = Private road or slow residenti…”
  • bollard_spacing_and_footing_calculator

    “Counts the bollards for a frontage and clear gap, checks the gap against vehicle and wheelchair guidance, gives typical footing and concrete for a standard (not crash rated) steel pipe bollard, and e…”

    Publisher declares: read-only yes

    10 inputs
    • frontage_ftnumber“Frontage to protect in feet (1 to 1,000).”
    • frontage_mnumber“Frontage to protect in metres.”
    • max_gap_innumber“Largest clear gap between bollards you will allow, in inches (12 to 120).”
    • max_gap_mmnumber“Largest clear gap in millimetres.”
    • pipestring“Nominal pipe size in inches (outside diameter 4.5, 6.625, 8.625, 10.75 in).”
    • endsstring“between-fixed-points: the frontage runs between two fixed obstructions such as walls, and the end gaps also count.”
    • footing_width_innumber“Footing width in inches (12 to 48).”
    • footing_shapestring“Footing shape.”
    • height_innumber“Pipe height above grade in inches (24 to 60).”
    • ratingstring“Optional crash rating to explain.”
  • steel_beam_lintel_span_check

    “The steel angle lintel or steel beam that the 2024 Ontario Building Code Part 9 tables list for an opening width in a brick or stone veneer wall or a masonry wall, with the 150 mm bearing rule.”

    Publisher declares: read-only yes

    5 inputs
    • opening_mmnumber“Clear opening width in millimetres (300 to 6,000).”
    • opening_ftnumber“Clear opening width in feet.”
    • wallstring“veneer-brick-70 = 70 mm brick veneer; veneer-brick-90 = 90 mm brick veneer; veneer-stone-100 = 100 mm stone veneer; solid-brick-100 = masonry wall, 100 mm bric…”
    • memberstring“angle = steel angle lintel; beam = steel beam supporting masonry veneer and a wood stud wall (veneer walls only).”
    • bearing_mmnumber“Optional: the bearing length you have at each end, to check against the 150 mm minimum.”
  • catch_basin_grate_and_frame_size_finder

    “Names the Ontario Provincial Standard Drawing for a catch basin inlet type, checks the grate bearing on the frame ledge against the NAAMM minimum, gives the range of bearing bar lengths that sit on t…”

    Publisher declares: read-only yes

    6 inputs
    • inletstring“square-flat = OPSD 400.020, General purpose frame and flat grate; square-dished = OPSD 400.010, Dished grate with an overflow path; square-v = OPSD 400.030, V …”
    • trafficstring“pedestrian = A 15; private-light = B 125; public-light = C 250; road-commercial = D 400; industrial = E 600; extreme = F 900.”
    • span_mmnumber“Clear opening between the frame ledges, in the direction the bearing bars will run, 100 to 3,000 mm.”
    • span_innumber“The same clear opening in inches.”
    • seat_mmnumber“Width of the ledge the grate sits on, each end, in millimetres (0 to 300).”
    • bar_depth_innumber“Depth of the grate bearing bars in inches (0.75 to 6), for example 1.25 or 2.5.”
Show 3 more tools
  • fence_and_gate_post_spacing_and_weight

    “Post count and spacing for a chain link or ornamental steel fence run, chain link footing depth and gate post size, and the weight and hinge loads of an ornamental steel gate leaf.”

    Publisher declares: read-only yes

    12 inputs
    • panelstring“chain-link (line posts 10 ft apart at most) or ornamental steel tubular pickets (8 ft, 96 in on center).”
    • run_ftnumber“Length of the fence run in feet, not counting the gate (3 to 2,000).”
    • height_ftnumber“Fence and gate height in feet (3 to 12).”
    • gate_ftnumber“Gate opening in feet, 0 for no gate (0 to 24).”
    • leavesstring“Single or double leaf gate.”
    • tube_innumber“Ornamental gate frame: square tube outside size in inches.”
    • wall_innumber“Ornamental gate frame: tube wall in inches (0.12 is about 11 gauge).”
    • picket_innumber“Ornamental gate: square picket size in inches.”
    • gap_innumber“Ornamental gate: largest gap between pickets in inches (4 in is the most the maker chart allows).”
    • mid_railsnumber“Ornamental gate: rails between the top and bottom rail.”
    • hinge_spacing_innumber“Distance between the two hinges in inches.”
    • post_od_innumber“Chain link line post outside diameter in inches, to get the footing diameter.”
  • trench_drain_flow_capacity_calculator

    “The flow a trench drain has to handle from a paved area (rational method with Toronto City rainfall rates from Environment and Climate Change Canada) and the flow the channel carries (Manning), with …”

    Publisher declares: read-only yes

    10 inputs
    • area_m2number“Paved area draining to the trench in square metres (1 to 100,000).”
    • area_sqftnumber“The same area in square feet.”
    • surfacestring“asphalt = Asphalt pavement; concrete = Concrete pavement; brick = Brick or interlocking paver; drive-walk = Driveway or walkway; roof = Roof; lawn-heavy-flat =…”
    • cnumber“Optional runoff coefficient C (above 0, up to 1) to use instead of the top of the range for the surface.”
    • periodstring“Return period in years.”
    • durationstring“Storm duration in minutes, taken as the time of concentration.”
    • width_mmnumber“Channel internal width in millimetres (50 to 1,000).”
    • depth_mmnumber“Water depth at the outlet end in millimetres (30 to 1,000).”
    • slope_pctnumber“Channel slope in percent (0.05 to 20).”
    • liningstring“concrete-trowel = Concrete, trowel finish; concrete-float = Concrete, float finish; concrete-unfinished = Concrete, unfinished; plastic-smooth = Smooth plastic.”
  • loading_dock_height_and_leveler_check

    “The grade a dock leveler works at between the lowest and highest truck bed you serve, against the 10% (electric) and 15% (gas or diesel) limits, the shortest standard leveler length that fits, and wh…”

    Publisher declares: read-only yes

    5 inputs
    • dock_height_innumber“Dock floor height above the driveway in inches (20 to 80).”
    • bed_low_innumber“Lowest truck bed height you serve, in inches (20 to 80).”
    • bed_high_innumber“Highest truck bed height you serve, in inches.”
    • leveler_ftstring“Leveler length in feet.”
    • equipmentstring“electric = pallet, skid or electric fork trucks (10% grade limit); combustion = gas or diesel fork trucks (15%).”

Each quoted sentence is the first sentence of the publisher’s own description. The kind of tool and the “changes data” mark are our AI model’s reading of that description, not something we tested: two differently worded runs had to agree, otherwise no label is shown, and nobody has checked them by hand. A tool without the “changes data” mark is described as only reading, searching or calculating, or the two runs did not agree. No tool was called. Read the publisher’s full description before relying on it. “Publisher declares” lists the hints the server itself sends with the tool (MCP annotations: read-only, destructive, idempotent, open-world); they are the publisher's claims, not checked by us. Inputs are the parameters in the tool's own input schema: name, declared type, whether it is required, and the first sentence of its description. Read 2026-11-17.

How well are its tools described?

Features #4 and #5

How clearly this server's own tool descriptions say what a tool does, and how consistent its tool list is. The first part is an AI model's yes/no reading of each description; the second part is counted. We do not turn it into a grade.

Descriptions

AI reading of each description

No AI reading was available for this server's tools (the two runs did not agree, or the listing was not reviewed).

Counted from the listing

Parameters with a description
100% of 107
Tools with a description
100% of 15
Typical description length
181 characters

The tool set

Counted from the listing

Tools
15
Size of the list
about 6,127 tokens for an agent to load (characters ÷ 4)
Naming
15 of 15 names use snake_case

AI reading: easy to mix up

No pair found.

The AI items cover 0 of 15 tools: for a tool where two differently worded runs disagreed, that item is left out. They were not checked by hand, and no tool was called. “Easy to mix up” means two tools whose names or descriptions overlap without saying how they differ; the AI found none. We do not rate whether the tool set is complete or whether side effects are spelled out, because our AI reading of those was not reliable enough.

How do I add it to my client?

Config from the registry entry

From the remote endpoint (Streamable HTTP)

We connected to this URL on 2026-11-17 (a read-only session: no tool was called).

Add to CursorAn install link in the format Cursor documents, holding the Cursor config below.

Claude Desktop or claude.ai
Settings → Connectors → Add custom connector, then paste:
https://thegrateguys.com/mcp
Cursor · .cursor/mcp.json in a project, or ~/.cursor/mcp.json
{
  "mcpServers": {
    "tools": {
      "url": "https://thegrateguys.com/mcp"
    }
  }
}
VS Code · .vscode/mcp.json
{
  "servers": {
    "tools": {
      "type": "http",
      "url": "https://thegrateguys.com/mcp"
    }
  }
}
VS Code (command line) · Bash or zsh terminal (macOS, Linux)
code --add-mcp '{"name":"tools","type":"http","url":"https://thegrateguys.com/mcp"}'
Claude Code
claude mcp add --transport http tools https://thegrateguys.com/mcp
Cline · cline_mcp_settings.json (Cline CLI: ~/.cline/data/settings/; in the editor: MCP Servers → Configure → Configure MCP Servers)
{
  "mcpServers": {
    "tools": {
      "type": "streamableHttp",
      "url": "https://thegrateguys.com/mcp",
      "disabled": false,
      "autoApprove": []
    }
  }
}
Gemini CLI · ~/.gemini/settings.json, or .gemini/settings.json in a project
{
  "mcpServers": {
    "tools": {
      "httpUrl": "https://thegrateguys.com/mcp"
    }
  }
}
OpenAI Codex · ~/.codex/config.toml, or .codex/config.toml in a trusted project
[mcp_servers.tools]
url = "https://thegrateguys.com/mcp"
Zed · Zed settings file (command: zed: open settings file)
{
  "context_servers": {
    "tools": {
      "url": "https://thegrateguys.com/mcp"
    }
  }
}
Try it in the MCP Inspector · runs on your machine, opens in your browser · Node 22.19+
npx @modelcontextprotocol/inspector@2.11.0 --server-url https://thegrateguys.com/mcp --transport http
  • The server runs on the operator's infrastructure; it may ask you to sign in when you first connect.
  • Zed's docs we read on 2026-10-26 describe remote servers by URL and do not name the transport.
  • The MCP Inspector lists the server's tools, resources and prompts; a tool you call there runs for real.

Built from the server's registry entry with each client's documented format (checked 2026-10-14; the Cursor link and the VS Code command 2026-10-19; the MCP Inspector command 2026-10-21; Cline, Gemini CLI, OpenAI Codex and Zed 2026-10-26). Values in < > are yours to fill in; this page never contains a key. Where the server needs a setting the entry does not declare, it can still fail to start.

What do the published files and outside lists say?

Read as text · nothing run · no tool called

Package files

  • MCP SDK in the package files. Not read yet: added with the next daily run.
  • Build workflow. Not read yet: added with the next daily run.

Outside lists

  • CVE records (NVD). No CVE record in the NVD feeds we read links this server's repository. Source: read 2026-11-17. This product uses the NVD API but is not endorsed or certified by the NVD.
  • GitHub advisories. No GitHub advisory names this entry's listed package. Source: read 2026-11-17. GitHub Advisory Database, CC BY 4.0
  • Docker MCP catalogue. Not in the Docker MCP catalogue on 2026-11-17. Source: read 2026-11-17.
  • Cline marketplace. Not in the Cline marketplace on 2026-11-17. Source: read 2026-11-17.

Own host

Read as text from published files and outside lists. Nothing was installed or run, and no tool was called. A fact, not a rating. How each fact is read

Does the registry listing match what we found?

Feature #6

The registry checks an entry when it is published (each new version), and nothing re-checks it on a schedule. A difference below is about the listing, not a judgement of the publisher.

Registry saysWe foundResultSource · date
Remote endpoint thegrateguys.com/mcpSession openedmatchesour test · 2026-11-17
No credential declared as requiredOpened a session without any credentialmatchesour test · 2026-11-17

Choosing

Record checks

Public records · not a safety rating

1 of 2 record checks met · 7 do not apply

  • Not ranked by downloads: a remote server publishes no download figure
  • Not ranked by stars: no public GitHub repository
  • MetRegistry entry is active and says how to run itActive, with a package or a remote address.
  • Not metSource repository link opensThe registry entry gives no repository link.What changes this check: This check opens the repository link in the registry entry. GitHub's documentation describes changing a repository's visibility in its Settings, under Danger Zone, Change visibility. GitHub: setting repository visibility
  • Does not applyRepository is not archivedNo public GitHub repository to read.
  • Does not applyCode pushed to the repository in the 90 days before our checkNo public GitHub repository to read.
  • Does not applyRepository publishes a security policy (SECURITY.md)No public GitHub repository to read.
  • Does not applyPackage names its licence with a standard (SPDX) identifierRemote server: it ships no package.
  • Does not applyThe version the registry lists can be installed and is not withdrawnRemote server: it ships no package.
  • Does not applynpm package carries build provenance (attestation)Remote server: it ships no package.
  • Does not applyNo known critical or high advisory in the package or its dependenciesRemote server: it ships no package.

Read from public records only: the registry entry, npm/PyPI, GitHub and advisory databases, checked 2026-11-17. No tool was called. Only “met” and “not met” are counted, so the total differs between servers; a check that does not apply or that we could not run is listed, never counted against it. It is not a safety rating, and the same rules apply to every server. How each check works · Leaderboards · How we stay neutral

Common questions about com.thegrateguys/tools

Answered from the data above

Who publishes com.thegrateguys/tools?

The registry ties the namespace com.thegrateguys to the domain thegrateguys.com; only its owner can publish under it. These are facts from the registry and GitHub, not a rating.

Does com.thegrateguys/tools need an API key or sign-in?

It opened a session without any credential on 2026-11-17. The registry entry declares no required credential; no declaration is not a guarantee.

Has com.thegrateguys/tools been security tested?

Partly. 2 of the 14 checks that apply to it were exercised. We connected and read what the server declares, but did not call its tools: ProtocolProbe calls no server's tools for anything it publishes, except for a server whose operator has claimed it and given permission (that server's page says so). This is our choice, not a block by the server. ProtocolProbe publishes no security verdict for a named server.

Found this page useful?

Anonymous · no sign-in

A quick, anonymous reaction — no account, no email. One per kind from your browser. The tally updates when the page is next refreshed, and it is only a rough count, never a safety rating or a measured number of people.

Compare with another server

Side by side: registry entry, our read-only session, the tools and the 18 classification fields. Same values as each page; no score.

Security testing

What did we test, and what did we leave out?

18 checks · features #1, #2

Not probed (no operator permission)

We connected and read what the server declares, but did not call its tools: ProtocolProbe calls no server's tools for anything it publishes, except for a server whose operator has claimed it and given permission (that server's page says so). This is our choice, not a block by the server. No security score is given; a check we did not run is never counted as passed.

The 18 checks at a glanceour test · 2026-11-17
  1. Inventory: exercised
  2. Hidden instructions: exercised
  3. Real execution: not run · our policy
  4. Secret leak: not run · nothing to check it against
  5. Internal addresses: not run · our policy
  6. Unconfirmed changes: not run · our policy
  7. Bad input: not run · our policy
  8. Model requests: not run · nothing to check it against
  9. Sensitive questions: not run · nothing to check it against
  10. Folder boundary: not run · our policy
  11. Log leaks: not run · nothing to check it against
  12. Hidden content: not run · nothing to check it against
  13. Fake assistant turns: not applicable
  14. Token passthrough: not applicable
  15. Token audience: not applicable
  16. Sign-in redirect: not run · our policy
  17. Consent handling: not testable from outside
  18. Sign-in metadata: not applicable

2 exercised12 not run (reason given)4 not applicable

Each check ends in exactly one state: exercised, not run (with the reason), or not applicable (with the reason). 2 of the 14 checks that apply to it were exercised. We do not publish security-check outcomes for named servers. These 18 checks are separate from the record checks at the top of this page, which read public records only.

Exercised · 2
  • 1Inventory
    tool-list
    Reads the declared tools, resources and prompts.exercised
  • 2Hidden instructions
    description-poisoning
    Looks for hidden instructions in tool descriptions.exercised
Not run, with the reason · 12
  • 3Real execution
    real-execution
    Calls a tool and checks what really happens.This check calls the server's tools. ProtocolProbe calls no server's tools for anything it publishes, except for a server whose operator has claimed it and given permission (that server's page says so); an operator can run this check on their own server with our self-test command.not run · our policy
  • 4Secret leak
    canary-leak
    Plants a fake secret and checks whether it leaks.This check needs at least one successful tool call to have something to check, and no tool was called.not run · nothing to check it against
  • 5Internal addresses
    ssrf
    Checks whether a tool can be steered to internal addresses.This check calls the server's tools. ProtocolProbe calls no server's tools for anything it publishes, except for a server whose operator has claimed it and given permission (that server's page says so); an operator can run this check on their own server with our self-test command.not run · our policy
  • 6Unconfirmed changes
    write-without-confirmation
    Checks whether tools that change data act without asking.This check calls the server's tools. ProtocolProbe calls no server's tools for anything it publishes, except for a server whose operator has claimed it and given permission (that server's page says so); an operator can run this check on their own server with our self-test command.not run · our policy
  • 7Bad input
    error-handling
    Sends bad input and watches how the server answers.This check calls the server's tools. ProtocolProbe calls no server's tools for anything it publishes, except for a server whose operator has claimed it and given permission (that server's page says so); an operator can run this check on their own server with our self-test command.not run · our policy
  • 8Model requests
    sampling
    Checks whether the server asks the client's model to act for it.This check needs at least one successful tool call to have something to check, and no tool was called.not run · nothing to check it against
  • 9Sensitive questions
    elicitation-sensitive-data
    Checks whether the server asks users for sensitive data.This check needs at least one successful tool call to have something to check, and no tool was called.not run · nothing to check it against
  • 10Folder boundary
    root-boundary
    Checks whether the server reaches outside the folders it was given.This check calls the server's tools. ProtocolProbe calls no server's tools for anything it publishes, except for a server whose operator has claimed it and given permission (that server's page says so); an operator can run this check on their own server with our self-test command.not run · our policy
  • 11Log leaks
    logging-side-channel
    Checks whether log messages carry data they should not.This check needs at least one successful tool call to have something to check, and no tool was called.not run · nothing to check it against
  • 12Hidden content
    audience-hiding
    Checks resources that hide content from the user.This check needs content the server returns, and nothing was read or called.not run · nothing to check it against
  • 16Sign-in redirect
    open-redirect
    Checks the sign-in redirect for abuse.Testing the sign-in redirect means sending probes to the operator's sign-in service, which we do not do.not run · our policy
  • 17Consent handling
    confused-deputy
    Checks consent handling when one service acts for another.Depends on the operator's own consent screen, which differs per server and cannot be tested from outside.not testable from outside
Does not apply to this server · 4
  • 13Fake assistant turns
    fake-assistant-turn
    Checks prompts that pose as the assistant's own words.The server exposes no prompts.not applicable
  • 14Token passthrough
    token-passthrough
    Checks whether the server forwards a user's token to other services.The server opened a session without sign-in, so there is no token flow to check.not applicable
  • 15Token audience
    token-audience-validation
    Checks whether tokens meant for another service are accepted.The server opened a session without sign-in, so there is no token flow to check.not applicable
  • 18Sign-in metadata
    oauth-url-scheme
    Checks the published sign-in metadata for unsafe URLs.No sign-in (OAuth) metadata is published, so there are no sign-in addresses to check.not applicable

Source: our own test, 2026-11-17, mcp-runtime-engine@0.1.0. Which checks count and why follows our published scoring model.

What happened during the test?

Feature #8

The steps in order, as the test record holds them.

  1. 0 msStarted a read-only session with the server's remote endpoint
  2. 323 msConnected after 0 redirects. No credential was sent or needed.
  3. Read the inventory: 15 tools, 0 resources, 0 prompts.
  4. 1,535 msFinished: 2 checks exercised.

Reference

How is it classified?

18 fields

One value per field, each with its source. Fields written by AI models are marked. A field with no value says why.

TopicAI-classified
pending: added at the next monthly refresh
listed 2026-11-17; not classified yet
Pricing modelAI-classified
not checked
no website in the registry entry
Programming language
does not apply
no existing GitHub repository (server declares no repository link, so there is nothing to fetch)
Hosting type
registry · 2026-11-17
MCP capability
tools
our test · 2026-11-17
Transport
streamable HTTP
registry · 2026-11-17
Required credentials
none declared
registry · 2026-11-17 · no declaration is not a guarantee
Package registry
does not apply
remote-only server: no package is shipped, so there is no package registry
Freshness
0–30 days
registry updatedAt · 2026-11-17
Lifecycle status
registry · 2026-11-17
License class
does not apply
remote-only server: ships no package, so there is nothing to look up in a package registry
Integrity hash
does not apply
remote-only server: ships no package, so there is nothing to look up in a package registry
Signature / provenance
does not apply
remote-only server: ships no package, so there is nothing to look up in a package registry
Dependency advisories
does not apply
ships no package, so there are no dependencies to audit
Popularity
does not apply
remote-only server: ships no package, so there is nothing to look up in a package registry
Publisher signals
not stated
no readable GitHub owner to describe
Maintenance
does not apply
server declares no repository link, so there is nothing to fetch
Environment
the publisher's infrastructure
where it runs, from the hosting type · 2026-11-17

“Not stated” means the source did not state it; “does not apply” means it does not apply to this kind of server; “our limit” means our own lookup failed. A linked value opens the directory filtered to the same value.

Cite or correct this page

Sources and corrections

Suggested citation

ProtocolProbe. “com.thegrateguys/tools: MCP server record.” Data checked 2026-11-17. https://protocolprobe.com/mcp/servers/com.thegrateguys/tools

Figures are valid for the date shown. Our facts on this page are CC BY 4.0: reuse them with a link and the check date. Quoted text (the publisher’s descriptions, website quotes, tool names) is not ours to license.

As JSON: this record in the API · API documentation.

Badge for your README

ProtocolProbe: 1 of 2 record checks met

[![ProtocolProbe](https://protocolprobe.com/api/v1/badge/com.thegrateguys/tools)](https://protocolprobe.com/mcp/servers/com.thegrateguys/tools)

It shows this server's record-check count: facts from public records, no tool called. It is not a security rating or a pass. It links here and updates after each data reload.

Something wrong, or is this yours?

If a fact here is wrong, tell us and we will re-check it. If you operate this server, you can run our checks on it yourself with the free self-test command; we call no server’s tools ourselves for anything shown here, except for a server whose operator has claimed it and given permission (that server's page says so).

Write to hello@protocolprobe.com · corrections log · methodology